CHNS/O MICRO ANALYSER |
- Model : Thermo Scientific Flash 2000 Organic Elemental Analyzer
- Sample size : 2-5 mg ( only powder samples can be analyzed)
- The technique involves the combustion of the testing sample in oxygen environment.
- Simultaneous CHNS determination as well as oxygen determination
- Highest degree of accuracy is ensured by complete conversion of sample to elemental gases without dilution or splitting.
- Oxygen is measured in a separate furnace which is maintaining at high temperature (10600c) in a carbon rich environment.
- Detector is Thermal Conductivity Detector (TCD)
|
tr>
FT-IR/ RAMAN SPECTROPHOTOMETER |
Model : Thermo Scientific - Nicolet iS50
|
Accessory |
Type of Sample |
Parameter /
mode
|
IR |
|
Solids |
Transmission |
ATR |
Films |
Specular Reflectance |
KBR |
Powder |
Diffused Reflectance |
|
DIFFERENTIAL SCANNING CALORIMETER (DSC) |
- Model : METTLER-TOLEDO & TA Instruments
- Temperature Range: -80deg to +450deg (for TA instrument)
- Temperature Range: -70deg to +500deg (for METTLER TOLEDO instrument)
- Phase transitions, such as melting, glass transitions, or exothermic decompositions can be studied.
- These Transitions involve energy changes or heat capacity changes that can be detected by DSC with great sensitivity.
- Melting point, Tm of polymer can be found. Tm depends on the molecular weight of the polymer
|
TIME RESOLVED FLUORESCENCE SPECTROPHOTOMETER (TRF) |
- Model : Horiba Jobin Yuvon Fluorocube -01-NL Fluorescence Life time System
- Picosecond laser diodes as excitation source.
- Optical pulse duration from < 70ps.
- Highly integrated picosecond PMT modules.
- Micro channel plate PMTs for the ultimate in time resolution.
- Used for Fluorescence Life time, Anisotropy and Steady state measurements.
|
LIQUID CHROMATOGRAPHY MASS SPECTROMETER |
- Model: Thermo Scientific (Ultimate 3000LC, LTQ XL)
- Detector: MS
- Columns Available: C 18
- Analysis: Separation of metabolites, peptides, proteins, organic and inorganic molecules.
|
GAS CHROMATOGRAPHY MASS SPECTROMETER |
- Models : Thermofisher - Trace 1300 (GC), ISQ 7000 (MS)
- Columns available : TG 5 MS
- Analysis: Separation of volatile metabolites, pesticides, chiral compounds
|
UV-VISIBLE SPECTROPHOTOMETER |
|
STOP FLOW SPECTROMETER |
- Model : BIO-LOGIC MOS-450/AF
- Range: 200 to 800nm
- For spectral recording in UV/Visible or Fluorescence spectroscopy is used.
- Fast recording modular spectrometer for rapid reaction kinetics and analysis.
- Filtered and non-sticky liquids can be measured
- Measuring Parameters
- Absorbance
- Fluorescence
- Light Scattering
- Fluorescence Anisotropy
|
INDUCTIVE COUPLED PLASMA OPTICAL EMISSION SPECTROPHOTOMETER (ICP-OES) |
- Model : AVIO 200
- For determination of composition and concentration of elementals in sample using plasma and spectrometer.
- Concentraiton ranging from 0.1ppm to 100ppm.
- Standards available for Ag, Al, As, Ba, Be, Bi, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, In, K, Li, La, Mg, Mn, Na, Ni, Pb, Rb, Se, Sr, Tl, U, V, Hg and Zn
- For elements other than mentioned above, user required to provide standards
|
POLARIZING MICROSCOPE |
- Model : Olympus BX-51
- Properties of organic or inorganic gels, liquid crystals and other substances can be studied.
- Heating and cooling of samples under observation between -80 and 600 degree Celsius is possible
|
FLUORESCENCE MICROSCOPE |
- Model : Olympus IX-71
- Properties of organic or inorganic gels, liquid crystals and other substances can be studied using Fluorescence and/or Phosphorescence
- Heating and cooling of samples under observation to an extent is possible
|
<